Skip Navigation



Alcohol and Alcoholism Advance Access published online on May 28, 2007

Alcohol and Alcoholism, doi:10.1093/alcalc/agm039
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
42/4/321    most recent
agm039v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Beck, O.
Right arrow Articles by Helander, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beck, O.
Right arrow Articles by Helander, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

The Author 2007. Published by Oxford University Press on behalf of the Medical Council on Alcohol.

Biomarkers to disclose recent intake of alcohol: potential of 5-hydroxytryptophol glucuronide testing using new direct UPLC-tandem MS and ELISA methods

Olof Beck1,*, Nikolai Stephanson1, Michael Böttcher2, Norbert Dahmen3, Christoph Fehr3 and Anders Helander4

1 Department of Medicine, Division of Clinical Pharmacology, Karolinska Institute and Karolinska University Hospital, Stockholm, Sweden
2 Arztpraxis für Medizinische Mikrobiologie und Labordiagnostik, Dessau, Germany
3 Department of Psychiatry, University of Mainz, Germany
4 Department of Clinical Neuroscience, Alcohol Laboratory, Karolinska Institute and Karolinska University Hospital, Stockholm, Sweden

* Author to whom correspondence should be addressed at: Karolinska University Hospital Solna, L7:05 Clinical Pharmacology, SE-171 76 Stockholm, Sweden. Tel: +46 8 51773026; Fax: +46 8 331343; E-mail: olof.beck{at}karolinska.se

Received 21 January 2007; first review notified 23 February 2007; in revised form 26 March 2007; accepted 30 March 2007


   Abstract

Aims: This study compared two new methods for direct determination of 5-hydroxytryptophol glucuronide (GTOL) in urine, a biomarker for detection of recent alcohol consumption. Methods: Urine samples were collected from ten alcoholic patients during recovery from intoxication. A direct injection ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for measurement of the urinary GTOL to 5-hydroxyindoleacetic acid (5-HIAA) ratio, and an ELISA assay for direct measurement of GTOL, were used. Comparison was made with the urinary ethanol and ethyl glucuronide (EtG) concentrations. Results: The breath ethanol concentration on admission ranged between 1.0–3.1 g/l. The UPLC-MS/MS method showed a median detection time of 39 h for an elevated urinary GTOL/5-HIAA ratio, while EtG was detected for a median of 65 h. Determination of GTOL by the ELISA assay showed 87% sensitivity in detecting positive samples at a 44% specificity, as compared with the UPLC-MS/MS method. Conclusions: The lower sensitivity of the urinary GTOL/5-HIAA ratio compared with EtG for recent drinking may be clinically useful, in cases where the EtG test provides an unwanted high sensitivity for intake of only small amounts of alcohol or unintentional ethanol exposure.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Alcohol AlcoholHome page
A. Helander, M. Bottcher, C. Fehr, N. Dahmen, and O. Beck
Detection Times for Urinary Ethyl Glucuronide and Ethyl Sulfate in Heavy Drinkers during Alcohol Detoxification
Alcohol Alcohol., January 1, 2009; 44(1): 55 - 61.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.